实时IT资产管理及人员管理数据中心无线环境监控USB2.0 USB3.0延长解决方案数据中心PDU智能管理数据中心制冷优化USB3.1 延长器USB3.0 延长器USB2.0 延长器USB1.1 延长器KVM+USB2.0 延长器ICRON 无线阅读器标签信号定位器RFID资产标签RFID环境标签RFID人员管理标签RFCODE管理应用软件RFCodeKVM高清矩阵KVM高清延长器VGA延长器USB延长器信号转换器机架配件及电源IHSE 延长器音视频矩阵NTI KVM切换器NTI 环境监控视频拼接器视频分配器KVM 分配器视频切换器USB/FireWireNTI Basic PDUMetered PDUSmart PDUSwitched PDUSmart POPS - Per Outlet Power Sensing PDUSwitched POPS - Per Outlet Power Sensing PDU-48 VDC Power ManagementFail-Safe Power RedundancyConsole Port Access & Remote Power ManagementSentry Power ManagerServer TechnologyData Center CurtainsData Center PartitionsData Center DoorsExpandable Filler PanelsData Center Mounting HardwareSimplexKoldlokHotlokAislelokEnergyLokUpsiteEDP LabelKVM 机架式一体机KVM 便携式一体机数据中心气流优化QDSMPU数字KVM系列数字串口ACS系列LCD+KVM一体机 智能机柜PDUAvocent视频延长器视频矩阵视频分频器DVI解决方案KM切换器HDMI解决方案机架解决方案KVM解决方案电视墙系统光纤延长器视频转换器远程电源Smart-AVI4K ExtendersExtendersOPHITKVMTEC控制台服务器Lantronix电源产品KVM系列产品Raritan
产品搜索
产品导航
ICRON-产品导航
 
RFCode-产品导航
 
IHSE-产品导航
 
Servertech PDU-产品导航
 
Upsite-产品导航
 
QDS-产品导航
 
NTI-产品导航
 
Avocent
 
Smart-AVI产品导航
 
OPHIT
 
Raritan
 
Simplex-产品导航
 
KVMTEC
 
Lantronix
 
产品品牌
Avocent
EDP Label
Humanscale
ICRON
IHSE
NetComstation
NTI
QDS
PlenaFrom
RFCode
ServerTech
Simplex
SceneDouble
Koldlok / Hotlok
Verity Sytems
在线客服
 工作时间
周一至周五 :8:30-17:30
CW-16HF2C452
类型: Fail-Safe Transfer
品牌: Server Technology
型号: CW-16HF2C452
产品详情

产品简介

The Sentry CW-16HF2/E Fail-SafeTM provides fail-over redundancy to single or dual-power supply servers and network devices. Exclusive to the Sentry Switched Fail-Safe is its ability to carry loads on the A circuit, B circuit or both and to remotely manage the outlets.

Similar, but unlike a common automatic transfer switch, the Sentry Switched Fail-Safe unit is unique in that it contains two (2) in-feeds and two (2) banks of eight (8) outlets each, for a total of 16 outlets across the two circuits.

The "A" in-feed routinely powers just the A1-8 outlets, and the "B" in-feed routinely powers just the B1-8 outlets. However, if the "A" in-feed goes down, the "B" in-feed powers all 16 outlets and the same if the "B" in-feed goes down, the "A" in-feed powers all the outlets.

This new "Fail-Safe" method has several advantages compared to a standard ATS because it does not prohibit load balancing between the two supplied circuits. A standard ATS contains two-in-feeds, but runs all outlets from just one source, with the secondary source only being used once an outage occurs on the capacity. This results in less heat, less resistance, and consequently less of a voltage drop compared to the same load existing on just one source. Only when an outage occurs on one of the two sources will the entire load be applied to a single source.

产品特点

Sentry  Cabinet PDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)
Fail-Safe CW-16HF2/E 208-240V
CW-16HF2A452
CX-16HF2A452*
208-240V 50/60Hz20A(2) IEC C20 Power Inlets(16) IEC 60320/C1317.2 x 3.50 x 10.0 in.
(437 x 89 x 254 mm)
CW-16HF2C452
CX-16HF2C452*
208-240V 50/60Hz30A(2) NEMA L6-30P Plugs, 10'(3m) Cord(16) IEC 60320/C1317.2 x 3.50 x 10.0 in.
(437 x 89 x 254 mm)
CW-16HFEA452
CX-16HFEA452*
230V 50/60Hz16A(2) IEC C20 Power Inlets(16) IEC 60320/C1317.2 x 3.50 x 10.0 in.
(437 x 89 x 254 mm)
CW-16HFEK452
CX-16HFEK452*
230V 50/60Hz32A(2) IEC Blue 2P+G Plug, 10'(3m) Cord(16) IEC 60320/C1317.2 x 3.50 x 10.0 in.
(437 x 89 x 254 mm)
*Indicates Expansion Unit
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10?(3m)
> PTCORD-2 IEC 60320/C19 - Schuko 10?(3m)
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10?(3m)
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10?(3m)
Additional Features and Specifications

Standards
> cTUVus ? UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS ? EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60905-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
   - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
     1 water sensor port
   - EMWS-1-1 Water Sensor