实时IT资产管理及人员管理数据中心无线环境监控USB2.0 USB3.0延长解决方案数据中心PDU智能管理数据中心制冷优化USB3.1 延长器USB3.0 延长器USB2.0 延长器USB1.1 延长器KVM+USB2.0 延长器ICRON 无线阅读器标签信号定位器RFID资产标签RFID环境标签RFID人员管理标签RFCODE管理应用软件RFCodeKVM高清矩阵KVM高清延长器VGA延长器USB延长器信号转换器机架配件及电源IHSE 延长器音视频矩阵NTI KVM切换器NTI 环境监控视频拼接器视频分配器KVM 分配器视频切换器USB/FireWireNTI Basic PDUMetered PDUSmart PDUSwitched PDUSmart POPS - Per Outlet Power Sensing PDUSwitched POPS - Per Outlet Power Sensing PDU-48 VDC Power ManagementFail-Safe Power RedundancyConsole Port Access & Remote Power ManagementSentry Power ManagerServer TechnologyData Center CurtainsData Center PartitionsData Center DoorsExpandable Filler PanelsData Center Mounting HardwareSimplexKoldlokHotlokAislelokEnergyLokUpsiteEDP LabelKVM 机架式一体机KVM 便携式一体机数据中心气流优化QDSMPU数字KVM系列数字串口ACS系列LCD+KVM一体机 智能机柜PDUAvocent视频延长器视频矩阵视频分频器DVI解决方案KM切换器HDMI解决方案机架解决方案KVM解决方案电视墙系统光纤延长器视频转换器远程电源Smart-AVI4K ExtendersExtendersOPHITKVMTEC控制台服务器Lantronix电源产品KVM系列产品Raritan
产品搜索
产品导航
ICRON-产品导航
 
RFCode-产品导航
 
IHSE-产品导航
 
Servertech PDU-产品导航
 
Upsite-产品导航
 
QDS-产品导航
 
NTI-产品导航
 
Avocent
 
Smart-AVI产品导航
 
OPHIT
 
Raritan
 
Simplex-产品导航
 
KVMTEC
 
Lantronix
 
产品品牌
Avocent
EDP Label
Humanscale
ICRON
IHSE
NetComstation
NTI
QDS
PlenaFrom
RFCode
ServerTech
Simplex
SceneDouble
Koldlok / Hotlok
Verity Sytems
在线客服
 工作时间
周一至周五 :8:30-17:30
Hotlok 10038
类型: 空置U高密封
品牌: Hotlok
型号: Hotlok 10038
产品详情

Hotlok 10038

产品简介

The HotLok® Blanking Panel is a snap-in blanking panel that seals the rack 29% better than the nearest competitor and helps you identify hotspots within minutes of installation. The cabinet temperatures are indicated in color-coded ranges, depending on location of temperature strip panel. The state-of-the-art technology, designed for both 1U and 2U openings, controls airflow for optimized cooling effectiveness.

HotLok® Blanking Panel with Temperature Strip is Upsite’s latest green solution for energy savings and reducing the carbon footprint of data centers.

产品特点

Both 1U and 2U configured versions achieve the following:

  • Reduce hotspots and bypass airflow by preventing equipment exhaust air or hot-aisle air from migrating to the conditioned air-intake stream at the front of the cabinet

  • Deliver lower temperature conditioned air to the upper one-third of the cabinet, typically the hottest area and most prone to equipment failure

  • Control airflow to save energy by adjusting cooling unit setpoints

Identify temperatures within a particular range, accurate to within +/- 1° C:

  • Blue: Recommended Operating Range based on recommendations from ASHRAE

  • Yellow: Allowable Operating Range based on equipment manufacturers’ recommendations for Class 1 IT equipment

  • Red: Outside Allowable Operating Range, indicates a definite risk

Additional Features:

  • Cantilevered sealing vanes eliminate the gap between adjoining Blanking Panels or with installed equipment

  • Tool-free, snap-in installationrequires no additional parts or components for installation

  • Easy-pull removal for any EIA-310-E standard openings using ergonomically designed finger grips

  • 1U Panels stack 10 high and 2U Panels stack 20 high for easy storage and ready availability

  • Upsite® Temperature Strip color-coded temperature ranges indicates potential hotspots by color based on ASHRAE Standard

  • HotLok® Blanking Panels with Temperature Strips are a prerequisite to all cooling configurations best practices including hot and cold aisle containment

收益

  • Use 1U and 2U versions on cabinets with standard 19-inch rail widths (483 millimeter)

  • Use with any standard EIA-310-E openings

  • Use version with Temperature Strips to determine the temperature at that position in the cabinet or install throughout to determine the range of temperatures from the top to the bottom of the cabinets

  • Use in a Hot and Cold Aisle layout for low or high heat density cabinets

  • Use in existing cabinets for optimization and standardization