产品详情
SEV-3203C
类型: Smart PDU
品牌: Server Technology
型号: SEV-3203C
产品详情

产品简介

A 42 outlet Smart PDU so you can pack more power and more devices into your data center racks. The high outlet count of mixed outlets makes the it the one PDU to power blade or traditional servers. The 42 outlets have a middle display that can be inverted, for overhead or under the floor power, and our next-generation locking receptacles. When paired with Server Technology's locking power cords, you'll have peace of mind knowing that your servers will stay safely plugged into the cabinet PDU. These network addressable Smart CDUs support an additional link unit using a single IP address as well as 4 temperature & humidity probes (2 via the master, 2 via the link unit).


产品特点

Sentry CDU Specifications
Item #Available Input
Voltages
Rated AmperageAvailable Input CordOutletsDimensions
(L x W x D)
Smart 240/415V 3phase 20/30A
STV-3203C
SEV-3203C*
240/415 V, 3-phase Wye, 50/60 Hz
20A (De-rated 16A)
IEC 60309 3P+N+G, 6hr (Red),
10 ft (3 m) cord
(36) IEC 60320/C13
(6) IEC 60320/C19
70.0 x 2.20 x 2.37 in.
(178 x 5.6 x 6.0 cm)
STV-3203D
SEV-3203D*
240/415 V, 3-phase Wye, 50/60 Hz
30A (De-rated 24A)
IEC 60309 3P+N+G, 6hr (Red),
10 ft (3 m) cord
(36) IEC 60320/C13
(6) IEC 60320/C19
70.0 x 2.20 x 2.37 in.
(178 x 5.6 x 6.0 cm)
STV-3203Z
SEV-3203Z*
240/415 V, 3-phase Wye, 50/60 Hz
30A (De-rated 24A)
NEMA L22-30P, 10 ft (3 m ) cord
(36) IEC 60320/C13
(6) IEC 60320/C19
70.0 x 2.20 x 2.37 in.
(178 x 5.6 x 6.0 cm)
*refers to the expansion unit
Additional Features and Specifications
Standards
TUV - US products
> US & Canada (cTUVus Mark) to UL 60950-1: 2007 and CAN/CSA 22.2 No. 60950-1-07
> FCC Class A, Part 15
> EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2 and v3
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)
> IPv4 and IPv6

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
- EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
- EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
1 water sensor port

Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.
Click here for the latest Firmware update.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
- Microsoft Active Directory (MSAD)
- Novell eDirectory (eDir)
- Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.