产品详情
STV-3101C
类型: Smart PDU
品牌: Server Technology
型号: STV-3101C
产品详情

产品简介

The STV-3101 product family provides high functionality in a 30 outlet smart PDU.  The Power Pivot flexible infeed provides simplified power cord routing to the PDU.  The Auto-Flip LED display provides the proper display orientation no matter how the PDU is mounted in the rack.  Combine these two features for a product that is truly compatible with either overhead busway or raised floor data center applications.

This Sentry PIPS CDU combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Combine the Sentry PIPS Smart Cabinet PDU with the Sentry Power Manager (SPM) software tool to gain power usage information across multiple Cabinet PDU's individual IP address.

This Smart cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.The Sentry cabinet PDU product family uniquely meets these demands.

The cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements.

产品特点


Sentry  CDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)
STV-3101 24xC13 and 6xC19 with PIPS
STV-3101C
SEV-3101C*
208-240V
50/60Hz
30ANEMA L6-30P Plug, 10'(3m), Power Pivot Cord(24) IEC 60320/C13
(6) IEC 60320/C19
60.0 x 1.75 x 2.25 in.
(152 x 4.4 x 5.7 cm)
STV-3101K
SEV-3101K*
230V
50/60Hz
32AIEC Blue 2P+G Plug, 10'(3m), Power Pivot Cord(24) IEC 60320/C13
(6) IEC 60320/C19
60.0 x 1.75 x 2.25 in.
(152 x 4.4 x 5.7 cm)
STV-3101B
SEV-3101B*
208-240V
50/60Hz
20ANEMA L6-20P Plug, 9'(2.74m), Power Pivot Cord(24) IEC 60320/C13
(6) IEC 60320/C19
60.0 x 1.75 x 2.25 in.
(152 x 4.4 x 5.7 cm)
STV-3101J
SEV-3101J*
230V
50/60Hz
16AIEC 60309 2P+G , 6 hr (blue), 2.72m (9 ft) Power Pivot Cord(24) IEC 60320/C13
(6) IEC 60320/C19
60.0 x 1.75 x 2.25 in.
(152 x 4.4 x 5.7 cm)
STV-3101G
SEV-3101G*
100-120V, 200-240V, 230V AC, 50/60 Hz20A, 16AInput cord ordered separately(24) IEC 60320/C13
(6) IEC 60320/C19
60.0 x 1.75 x 2.25 in.
(152 x 4.4 x 5.7 cm)
*SEV refers to the Expansion Module
Input Cord Options for C20 Inlets
Part NameVoltageDescription


PTCORD-L1200-240V ACLocking IEC 60320/C19 - L6-20P (20A Twist-Lock) 10ft (3m), 12 AWG, cULus


PTCORD-L2230V ACLocking IEC 60320/C19 - CEE 7/7 Schuko 10ft (3m), 1.50 mm(sq)


PTCORD-L3230V ACLocking IEC 60320/C19 - Blue IEC 60309 "Commando" plug, 2P+E, 6 Hr. ground, 16A, 220-250V, IP20, 10ft (3.0m), 1.50 mm(sq)


PTCORD-L4230V ACLocking IEC 60320/C19 - BS1363 13A (UK) 10ft (3m), 1.50 mm(sq)


PTCORD-L5100-120V ACLocking IEC 60320/C19 - 5-15P (15A Straight-Blade) 10ft (3m), 14AWG, cULus approval


PTCORD-L6100-120V ACLocking IEC 60320/C19 - 5-20P (20A Straight-Blade) 10ft (3m), 12 AWG, cULus approval


PTCORD-L7100-120V ACLocking IEC 60320/C19 - L5-20P (20A Twist-Lock) 10ft (3m), 12 AWG, cULus approval


Additional Features and Specifications

Standards
> US & Canada (cTUVus Mark) to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07
> European Union (TUVGS Mark) to EN 60950-1: 2006 + A11
> FCC Class A, Part 15
> CE Mark
> EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2 and v3
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)
>IPv4 and IPv6

Branch Circuit Protection
> Compliant to UL 60950-1

Outlets
> High Retention Locking Receptacles: All STV-3101 PDUs utilize high retention receptacles to provide additional security when used with conventional power cords.  Each PDU is also fully compatible with Server Technology's locking power cord solutions (supplied separately).  

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
   - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
     1 water sensor port

Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.
Click here for the latest Firmware update.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
 - Microsoft Active Directory (MSAD)
 - Novell eDirectory (eDir)
 - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.