实时IT资产管理及人员管理数据中心无线环境监控USB2.0 USB3.0延长解决方案数据中心PDU智能管理数据中心制冷优化USB3.1 延长器USB3.0 延长器USB2.0 延长器USB1.1 延长器KVM+USB2.0 延长器ICRON 无线阅读器标签信号定位器RFID资产标签RFID环境标签RFID人员管理标签RFCODE管理应用软件RFCodeKVM高清矩阵KVM高清延长器VGA延长器USB延长器信号转换器机架配件及电源IHSE 延长器音视频矩阵NTI KVM切换器NTI 环境监控视频拼接器视频分配器KVM 分配器视频切换器USB/FireWireNTI Basic PDUMetered PDUSmart PDUSwitched PDUSmart POPS - Per Outlet Power Sensing PDUSwitched POPS - Per Outlet Power Sensing PDU-48 VDC Power ManagementFail-Safe Power RedundancyConsole Port Access & Remote Power ManagementSentry Power ManagerServer TechnologyData Center CurtainsData Center PartitionsData Center DoorsExpandable Filler PanelsData Center Mounting HardwareSimplexKoldlokHotlokAislelokEnergyLokUpsiteEDP LabelKVM 机架式一体机KVM 便携式一体机数据中心气流优化QDSMPU数字KVM系列数字串口ACS系列LCD+KVM一体机 智能机柜PDUAvocent视频延长器视频矩阵视频分频器DVI解决方案KM切换器HDMI解决方案机架解决方案KVM解决方案电视墙系统光纤延长器视频转换器远程电源Smart-AVI4K ExtendersExtendersOPHITKVMTEC控制台服务器Lantronix电源产品KVM系列产品Raritan
产品搜索
产品导航
ICRON-产品导航
 
RFCode-产品导航
 
IHSE-产品导航
 
Servertech PDU-产品导航
 
Upsite-产品导航
 
QDS-产品导航
 
NTI-产品导航
 
Avocent
 
Smart-AVI产品导航
 
OPHIT
 
Raritan
 
Simplex-产品导航
 
KVMTEC
 
Lantronix
 
产品品牌
Avocent
EDP Label
Humanscale
ICRON
IHSE
NetComstation
NTI
QDS
PlenaFrom
RFCode
ServerTech
Simplex
SceneDouble
Koldlok / Hotlok
Verity Sytems
在线客服
 工作时间
周一至周五 :8:30-17:30
CS42CS-4PKE2S000
类型: Smart PDU
品牌: Server Technology
型号: CS42CS-4PKE2S000
产品详情

产品简介

The Server Technology Smart CDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides highly-accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart “Master" CDU can be connected to the Smart “Link" CDU to extend the network access to the redundant or secondary power feed.
HDOT
The highest possible outlet density available in a network connected PDU. Up to 42 C13's in a 42U high by 1U wide device. Additional features include high native cord retention that eliminates the need for custom and costly ancillary locking cord devices. Manufactured with robust high temperature materials carrying a UL94 V-0 ame rating makes these outlets ideally suited for harsh data center environments.


产品特点


Sentry  CDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)
CS39CS-D/Y 208V 3-Phase 20/30A with PIPS
CS42CS-4NKE2S000
CL42CS-4NKE2S000*
220-240V L-N Nominal,50/60Hz
≤16AIEC 60309 6hr 3P+N+PE Red,3m, 5-C, H05VV-F, 4.0mm2(42) IEC 60320/C1370.1 x 1.75 x 2.25 in
(3" deep at breakers)
CS42CS-4PKE2S000
CL42CS-4PKE2S000*
220-240V L-N Nominal,50/60Hz≤32AIEC 60309 6hr 3P+N+PE Red,3m, 5-C, H05VV-F, 4.0mm2(42) IEC 60320/C1370.1 x 1.75 x 2.25 in
(3" deep at breakers)
* CL part numbers refer to the Expansion CDU
Additional Features and Specifications
Standards
• TUVGS Mark to EN 60950-1:2006 + A11
• EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
• FCC Class A, Part 15
• CE Mark
• RoHS/WEEE

Communications
• 10/100 Mbps Ethernet (RJ-45 connector)
• RS-232 serial (RJ-45 connector)
• Two (2) temperature/humidity sensor inputs (4P4C)
• Link port (RJ-12)
• Web-browser GUI and command-line-interface (CLI)
HTTP/HTTPS, SSLv3/TLSv1, SSHv2, Telnet, SNMPv2c and v3 (GET,
SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS

Branch Circuit Protection
• UL489 compliant circuit breakers, 1-pole, 20A
• Six (6) branches
• Current Rating: ≤ 16A
• Voltage Rating: 220V-240V nominal, 50/60Hz

Accessories
• EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
• EMCU-1-1B Environmental Monitor adding:
-Two (2) EMTH-1-1 temperature/humidity ports (one probe included)
-One (1) EMWS-1-1 water sensor port (probe sold separately)
-Four (4) dry contact (NO/NC) monitoring points
-One (1) 8-bit analog-to-digital converter (0 to 5VDC)
• SPM (Sentry Power Manager):
-Monitor and manage multiple PDUs from a single point
-Monitor and manage alarm conditions
-Create reports and trends on stored data
-Analyze power usage per phase
-Optional appliance or virtual version
-VMware Ready
• Device / Output Locking Power Cords
-Multiple options available
-Contact Server Technology for details.
• Mounting Brackets
-Buttons (KIT-0020) included for tool-less mounting.

Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.
Click here for the latest Firmware update.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
 - Microsoft Active Directory (MSAD)
 - Novell eDirectory (eDir)
 - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.