实时IT资产管理及人员管理数据中心无线环境监控USB2.0 USB3.0延长解决方案数据中心PDU智能管理数据中心制冷优化USB3.1 延长器USB3.0 延长器USB2.0 延长器USB1.1 延长器KVM+USB2.0 延长器ICRON 无线阅读器标签信号定位器RFID资产标签RFID环境标签RFID人员管理标签RFCODE管理应用软件RFCodeKVM高清矩阵KVM高清延长器VGA延长器USB延长器信号转换器机架配件及电源IHSE 延长器音视频矩阵NTI KVM切换器NTI 环境监控视频拼接器视频分配器KVM 分配器视频切换器USB/FireWireNTI Basic PDUMetered PDUSmart PDUSwitched PDUSmart POPS - Per Outlet Power Sensing PDUSwitched POPS - Per Outlet Power Sensing PDU-48 VDC Power ManagementFail-Safe Power RedundancyConsole Port Access & Remote Power ManagementSentry Power ManagerServer TechnologyData Center CurtainsData Center PartitionsData Center DoorsExpandable Filler PanelsData Center Mounting HardwareSimplexKoldlokHotlokAislelokEnergyLokUpsiteEDP LabelKVM 机架式一体机KVM 便携式一体机数据中心气流优化QDSMPU数字KVM系列数字串口ACS系列LCD+KVM一体机 智能机柜PDUAvocent视频延长器视频矩阵视频分频器DVI解决方案KM切换器HDMI解决方案机架解决方案KVM解决方案电视墙系统光纤延长器视频转换器远程电源Smart-AVI4K ExtendersExtendersOPHITKVMTEC控制台服务器Lantronix电源产品KVM系列产品Raritan
产品搜索
产品导航
ICRON-产品导航
 
RFCode-产品导航
 
IHSE-产品导航
 
Servertech PDU-产品导航
 
Upsite-产品导航
 
QDS-产品导航
 
NTI-产品导航
 
Avocent
 
Smart-AVI产品导航
 
OPHIT
 
Raritan
 
Simplex-产品导航
 
KVMTEC
 
Lantronix
 
产品品牌
Avocent
EDP Label
Humanscale
ICRON
IHSE
NetComstation
NTI
QDS
PlenaFrom
RFCode
ServerTech
Simplex
SceneDouble
Koldlok / Hotlok
Verity Sytems
在线客服
 工作时间
周一至周五 :8:30-17:30
CS-2HDYM131Z1
类型: Smart PDU
品牌: Server Technology
型号: CS-2HDYM131Z1
产品详情

产品简介

The dual input, dual output Smart Power Monitor allows the ability to easily add input current load and power monitoring to any existing cabinet via an integral web based interface or through a serial connection.


This allows you to determine:
1) if there is available power to add additional devices to the cabinet.
2) if you are close to exceeding the circuit's capacity potentially leading to an over current protection device tripping and bringing down the input feed.
3) if each CDU is properly loaded to ensure redundancy when one of the two input feeds is lost.

This product is perfect for large storage solutions like SAN's where the CS-2HD can be added to existing installations to determine the power draw of these systems.
Note: In an A and B power input-feed configuration, each Cabinet Power Distribution Unit (CDU) should not be loaded to over 40% of the rated capacity to ensure that if one of the two power feeds is lost that the whole load can be supported by the remaining CDU.


产品特点

Sentry  Cabinet PDU Specifications
Item #Input
Voltages
Rated
Amperage
InputsOutputsDimensions
(L x H x D)
CS-2HDD/HDY-3Ph
CS-2HDDD131Z13-Phase Delta, 208V,
50/60 Hz
20A(2) NEMA L15-20P
Cord Set, 10ft (3.0m)
(2) NEMA L15-20R
Cord Set, 3ft (.9m)
1.75"x17.0"x10.0"
(44x432x254mm)
CS-2HDDE131Z13-Phase Delta, 208V,
50/60 Hz
30A(2) NEMA L15-30P
Cord Set, 10ft (3.0m)
(2) NEMA L15-30R
Cord Set, 3ft (.9m)
1.75"x17.0"x10.0"
(44x432x254mm)
CS-2HDYL131Z13-Phase Wye, 208V,
50/60 Hz
20A(2) NEMA L21-20P
Cord Set, 10ft (3.0m)
(2) NEMA L21-20R
Cord Set, 3ft (.9m)
1.75"x17.0"x10.0"
(44x432x254mm)
CS-2HDYM131Z13-Phase Wye, 208V,
50/60 Hz
30A(2) NEMA L21-30P
Cord Set, 10ft (3.0m)
(2) NEMA L21-30R
Cord Set, 3ft (.9m)
1.75"x17.0"x10.0"
(44x432x254mm)
Additional Features and Specifications
Standards
> cTUVus – UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS – EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)